SRD 125/250
BOGE SRD 250 industrial compressor assembly
.
Piston compressor: Automatic, air-cooled, oil lubricated
.
– Compressor and motor directly coupled
.
– Cooling and monitoring equipment installed ready for operation
.
– Ducted cooling air via cylinder and aftercooler
.
– Cooling air hood also functions as fan guard
.
– Very efficient heat exchange through high capacity copper aftercooler
.
– Long service life of the frictionless, wear resistant ferax® tongue valve
.
– Low oil carry-over due to honed cylinder walls
.
– Quiet running due to precision balanced crank shaft
.
– Minimal further air treatment required due to low compressed air outlet temperature
.
– Vibration absorbed through flexible mountings
.
– Surface coating in light blue, RAL 5012
.
– Filled with oil as standard
.
– Suction filter
.
Technical Data:
.
Maximum pressure................................................................................................... 10.. bar
.
Suction capacity (displacement)............................................................................ 250.. l/min
.
Number of cylinders / number of stages............................................................... 2 / 1..
.
Compressor rotational speed................................................................................ 1400.. 1/min
.
Average piston speed............................................................................................ 2,12.. m/s
.
Rated power of drive motor................................................................................... 1,50.. kW
.
Protection type / Insulation class of the motor................................................ IP 54 / F..
.
Operating voltage................................................................................... 400 V / 50 Hz..
.
Control voltage.............................................................................................. 230 V AC..
.
Cooling air flow volume (acc. to VDMA regulation 4363)................................. 640,00.. m³/h
.
Suction or ambient temperature (min...max).................................................. +5...+45.. °C
.
Residual oil content in compressed air.................................................................. 0,10.. g/kWh
.
Unit sound pressure level (in accordance with DIN/PN8NTC2.3)........................... 82.. dB(A)
.
Dimensions and weight (according to dimensioned drawing):............ M 3100.0039..
.
Width / Depth / Height........................................................................... 485 / 351 / 340.. mm
.
Compressed air connection............................................................................... DN 12..
.
Weight.................................................................................................................... 38,0.. kg
.
Subject to technical modifications